Hyperion Energy Systems LLC · Arizona, United States ACC 25064658 support@thesunseekers.net
HYPERION. Request quote
ResidentialCommercial Utility scaleTelecom

Storage sized for the load you actually have

Most projects are specified from a catalogue page and corrected on site. We work the other way round — duty cycle first, then chemistry, then the compliance pack your jurisdiction will actually ask for.

0Cycles at 0.5C, 80 % DoD, 25 °C
0DC round-trip efficiency
0Per 20 ft container
UN 38.3On every shipment, without exception

Products

Six families, from a wall-mounted pack to a 5 MWh container. Minimum order is one unit on every line. Prices are confirmed in writing against your configuration and destination.

01 Residential Storage
5 – 30 kWh · 51.2 V

Residential Storage

Wall-mounted and stackable LFP for solar self-consumption and whole-home backup, matched to the hybrid inverter already specified for the project.

  • Usable capacity5.1 – 30.7 kWh
  • Nominal voltage51.2 V
  • ChemistryLiFePO₄
  • Cycle life≥ 6 000 @ 0.5C 80 % DoD
Minimum order1 unit
Price rangeUS$10,000 – 30,000
PurchasingContact sales
02 C&I Cabinet
100 – 500 kWh cabinet

C&I Cabinet

Outdoor all-in-one cabinets for peak shaving and demand-charge management. Battery, PCS, EMS, thermal management and fire suppression integrated and tested as one unit.

  • Capacity100 – 500 kWh
  • Power rating50 – 250 kW
  • CoolingLiquid / forced air
  • EnclosureIP54 / IP55
Minimum order1 unit
Price rangeUS$40,000 – 150,000
PurchasingContact sales
03 Containerised BESS
20 ft · 3.4 – 5 MWh

Containerised BESS

Utility-scale 20-foot systems for renewable firming, frequency response and capacity markets. Liquid-cooled, 1500 V DC, delivered with the full compliance and commissioning pack.

  • Capacity per unit3.44 – 5.0 MWh
  • DC architecture1500 V
  • C-rate0.25C – 1C
  • CoolingLiquid
Minimum order1 unit
Price rangeUS$500,000 – 1,000,000
PurchasingContact sales
04 LFP Cells & Modules
280 / 314 / 320 Ah

LFP Cells & Modules

Grade-A prismatic cells and pre-assembled modules for pack builders, supplied with matched capacity and internal resistance so the pack balances the way the BMS expects.

  • Cell capacity280 / 314 / 320 Ah
  • Nominal voltage3.2 V
  • GradingGrade A, matched
  • Cycle life≥ 6 000 – 8 000
Minimum order1 unit
Price rangeUS$30,000 – 90,000
PurchasingContact sales
05 Telecom & Data Centre Racks
48 V · 19-inch rack

Telecom & Data Centre Racks

Rack batteries for telecom sites, UPS replacement and data-centre backup. Drop-in footprint for VRLA strings with parallel operation and real state-of-charge telemetry.

  • Nominal voltage48 V / 51.2 V
  • Capacity50 – 200 Ah
  • Form factor19" rack, 2U – 4U
  • ParallelUp to 16 units
Minimum order1 unit
Price rangeUS$30,000 – 60,000
PurchasingContact sales
06 BMS, PCS & EMS
BMS · PCS · EMS

BMS, PCS & EMS

Battery management, power conversion and energy management selected and configured together — including the protocol work that makes third-party inverters and site SCADA talk to the battery.

  • BMS layersCell / module / rack
  • PCS range30 kW – 2.5 MW
  • ProtocolsModbus, CAN, SNMP
  • ComplianceUL 1741, IEEE 1547
Minimum order1 unit
Price rangeUS$30,000 – 200,000
PurchasingContact sales

Four duty cycles, four different machines

Storage is not one product. What the system is for decides the chemistry, the cooling, the C-rate and the certification it needs.

500kWh per cabinet
0.5Cstandard rate

Commercial peak shaving

Shaving the monthly peak that sets the demand charge. We size against your interval data, not a rule of thumb, and state the payback arithmetic rather than asserting it.

5.0MWh per container
1500V DC architecture

Utility-scale firming

Smoothing renewable output and bidding into ancillary markets, with the augmentation plan built into the twenty-year model from day one rather than discovered in year three.

30.7kWh stackable
90% usable DoD

Solar self-consumption

Shifting midday generation into the evening peak and keeping the lights on when the grid drops. Sizing follows the household load profile, not the size of the array.

10year design life
16units in parallel

Telecom & data centre backup

Lithium replacing VRLA strings — a quarter of the weight, several times the cycle life, and real state-of-charge telemetry instead of a float voltage and a guess.

Why sizing comes first

A battery that is wrong for the duty fails slowly

It does not break on day one. It degrades faster than the model said, misses the peak it was bought to shave, and the warranty claim fails because the duty cycle was outside the tested conditions all along.

Every number we quote carries the conditions it was measured under — C-rate, depth of discharge and temperature. Without them a specification is decoration.

How a project runs

The value of an integrator sits in the steps between your purchase order and a commissioned system.

01

Define the duty

Energy, power, cycles per day, ambient conditions and the grid code. Interval data where you have it.

02

Size and select

Configuration, chemistry, cooling and C-rate, with the degradation curve and any augmentation plan stated up front.

03

Integrate

BMS, PCS and EMS configured together, protocols verified against your inverter and SCADA rather than assumed.

04

Test and ship

Factory acceptance test to an agreed protocol, then class 9 dangerous-goods shipment with the full document pack.

05

Commission

Commissioning support, handover documentation and a named contact for warranty and service.

NEXT

Start at step one

Request a quote

What ships with every system

Lithium is class 9 dangerous goods and a permitted installation. Without the paperwork the shipment does not move and the system does not get signed off.

UN 38.3 test report

Required for air and sea transport of every lithium shipment.

MSDS / SDS

Safety data sheet for the cell chemistry, in the destination's format.

Cell and module test data

Capacity, internal resistance and OCV traceable to serial number.

Factory acceptance test

System-level FAT before despatch, protocol agreed in advance.

Certification pack

UL, IEC and CE certificates, issued in the certificate holder's name.

Dangerous goods declaration

Class 9 documentation and packing certification for the carrier.

Next step

Know your load profile?

Send the energy, power and duty cycle. We come back with a sized configuration, the compliance pack it needs for your jurisdiction, and a lead time in writing.